The EHA AC Load Break Switch is a versatile and reliable solution designed for safe and efficient isolation of low-voltage circuits, particularly in machine control applications. Available in 3 or 4 poles with a current range of 160 to 800A, the EHA100 ensures reliable performance by making and breaking circuits under load conditions. With its modular design and wide range of accessories, the EHA100 can be transformed into a multipolar load break switch or a 3/4 pole changeover switch for on-load switching between two power sources or circuits, while maintaining safety isolation.
AC Load Break Disconnector switch is a type of equipment that isolates the power failure part from the live part and creates a clear break point to isolate the faulty equipment or carry out the maintenance.
A Load break switch is similar in structure to a disconnector (both have visible disconnection points in the disconnection state), but it can be used to open and close circuits, which in turn resembles a circuit breaker.
However, a circuit breaker can control any circuit, while aLoad break switch can only switch on or off load current, or switch off over load current, so it is only used to switch off and on circuits under normal conditions, not short circuit fault current. However, it is required that its structure can pass the fault current of short circuit time without damage.
Because the arc extinguishing device and contact of the Load break switch are designed to cut off and connect the load current, the Load break switch should be used with the fuse in most cases, and the latter is responsible for cutting off the short-circuit fault current.
The opening and closing frequency and operating life of load disconnecting switches are usually higher than those of circuit breakers.
Load break switches are devices used to open an electrical circuit by isolating the source from the consumer. Whether they are manual, motorised or with a trip function, these devices ensure the on-load making, breaking and safety disconnection of low-voltage electrical circuits. Easy to assemble and easy to use, they are suitable for structures evolving in the industrial sector, public distribution, as well as emergency switching, distribution panels and motor feeders.
Modular device
Product Name |
High Voltage AC Isolation Switch
|
Model | EHA |
Rated Current | 160/250/315/400/630/800A |
Rated Voltage | 500/690/1000VAC |
Pole Array | 02, 11, 03, 12, 04, 22, 20, 21, 30, 40 |
Rated Current (Ie) | 160A | 250A | 315A | 400A | 630A | 800A |
---|---|---|---|---|---|---|
Frame Size | EHA-315 | EHA-315 | EHA-315 | EHA-630 | EHA-630 | EHA-630 |
Thermal Current (Ith) | 160 | 250 | 315 | 400 | 630 | 800 |
Rated Insulation Voltage (Ui) | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 |
Rated Impulse Withstand Voltage (Uimp) | 12 | 12 | 12 | 12 | 12 | 12 |
Utilization Category | AC-20A/AC-20B AC-21A/AC-21B AC-22A/AC-22B AC-23A/AC-23B |
AC-20A/AC-20B AC-21A/AC-21B AC-22A/AC-22B AC-23A/AC-23B |
AC-20A/AC-20B AC-21A/AC-21B AC-22A/AC-22B AC-23A/AC-23B |
AC-20A/AC-20B AC-21A/AC-21B AC-22A/AC-22B AC-23A/AC-23B |
AC-20A/AC-20B AC-21A/AC-21B AC-22A/AC-22B AC-23A/AC-23B |
AC-20A/AC-20B AC-21A/AC-21B AC-22A/AC-22B AC-23A/AC-23B |
Short-Circuit Capacity (1000VAC, No Protection) | ||||||
Rated Short Time Withstand Current (Icw 1s, kAeff) | 8 | 8 | 11 | 11 | 11 | 11 |
Rated Short-Circuit Making Capacity (Icm, kA peak, 60ms) | 22 | 22 | 22 | 22 | 22 | 22 |
Cable Recommendations | ||||||
Recommended Cu Rigid Cable Cross Section (mm²) | 70 | 120 | 185 | 240 | 2 × 185 | 2 × 240 |
Recommended Cu Busbar Width (mm) | 20 | 20 | 25 | 25 | 25 | 25 |
Mechanical Characteristics | ||||||
Durability (Number of Operating Cycles) | 8000 | 8000 | 8000 | 8000 | 8000 | 8000 |
Number of Cycles of Operation with Current | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 |
Easy to install
Safe reliable operation
Designed for harsh environments
Installation requirements