Aswich Edb 4p 1000V Solar Energy Photovoltaic PV Switch MCB DC Circuit Breaker

Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: Air
Installation: Fixed
Structure: MCB
Samples:
US$ 18/Piece 1 Piece(Min.Order)
| Request Sample
Customization:

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
EDB1-63 series
Poles Number
1p/2p/3p/4p
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
ISO9001-2000, CE, CB, CCC, SAA
Voltage Ui
1000V
Current
63A
Transport Package
by Sea/Air
Specification
box
Trademark
Aswich
Origin
China
HS Code
853650
Production Capacity
1000000PC/Year

Product Description

Parameter Description Unit Value
Rated Voltage V 250V/500V/750V/1000V
Rated current A 6,10,16,20,32,40, 63
Power        frequency        withstand
Voltage
kVrms 4
Impulse withstand Voltage kVpk 6/10
Tripping Characteristic type   Type B Type C
Instantaneous Tripping range
according to IEC/EN 60898-1
  3-5x 1 3-10x
Rated breaking capacity kA 6/10 6/10
Energy Limitation Class   3 3
Mounting   DIN rail (DIN EN50052)
Mechanical Endurance cycles 20,000
Electrical Endurance cycles 10,000
Conductor Size mm2 Up to 25
Degree of protection IP 55

 tests in accordance with IEC 60898-1:
  1. Indelibility of Marking
    1. Resistance to heat
    2. Resistance to abnormal heat and to fire
    3. Resistance to rusting.
    4. Resistance to Mechanical shock and Impact
    5. Short-Circuit
    6. Mechanical and Electrical endurance
    7. Tripping Characteristic
    8. Temperature rise
    9. Dielectric Properties
    10. Protection against electric shock
    11. Reliability of terminals for external conductors
    12. Reliability of Screws, Current carrying parts and connections

Why should 4P DC circuit breaker be selected for DC1000V?

1. Direct current is more dangerous than alternating current.

2. The short circuit circuit normally has hundreds of amps to thousands of amps. When the 2P DC circuit breaker is used in the DC1000V service, the subsection capability is greatly reduced and the safety is greatly reduced, so it is necessary to connect the circuit breaker in series to improve the subsection capability and the service safety

3. 2P DC circuit breaker is easy to burn off after short circuit, 4P DC circuit breaker can be used for many times after short circuit
 

Detail
Aswich Edb 4p 1000V Solar Energy Photovoltaic PV Switch MCB DC Circuit BreakerAswich Edb 4p 1000V Solar Energy Photovoltaic PV Switch MCB DC Circuit BreakerAswich Edb 4p 1000V Solar Energy Photovoltaic PV Switch MCB DC Circuit BreakerAswich Edb 4p 1000V Solar Energy Photovoltaic PV Switch MCB DC Circuit Breaker




About us



Aswich Edb 4p 1000V Solar Energy Photovoltaic PV Switch MCB DC Circuit BreakerAswich Edb 4p 1000V Solar Energy Photovoltaic PV Switch MCB DC Circuit Breaker

Aswich Edb 4p 1000V Solar Energy Photovoltaic PV Switch MCB DC Circuit Breaker


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now